pubmed.go-v.org

Energy Transfer Assisted Fast X‐ray Detection in Direct/Indirect Hybrid Perovskite Wafer

Metal halide perovskite scintillators encounter unprecedented opportunities in indirect ionizing radiation detection due to their high quantum yields. However, the long scintillation lifetime of microseconds upon irradiation, known as the afterglow phenomenon, obviously limits their fast development. Here, a new type of hybrid X‐ray detector wafer combining direct methylamine lead iodide (MAPbI3) semiconductor and indirect zero‐dimensional cesium copper iodide (Cs3Cu2I5) scintillator through low‐cost fast tableting processes is reported. Due to the fast energy transfer from Cs3Cu2I5 to MAPbI3, the device response time to X‐rays is dramatically reduced by nearly 30 times to 36.6 ns, which enables fast X‐ray detection capability by a large area detector arrays within 1 s. Moreover, Cs3Cu2I5 exists at the grain boundaries of MAPbI3 crystals, and blocks the paths of mobile ions of perovskite, leading to the lowest detectable dose rate of hybrid X‐ray detector is thus reduced by 1.5 times compared with control MAPbI3 direct‐type semiconductor, and 10 times compared with the Cs3Cu2I5 indirect‐type scintillator. The direct/indirect hybrid wafer also exhibits improved operation stability a

source: PubMed Central Open Access Subsetlicence: Per-article PMC Open Access licencedatabase: /dbs/pmc.dbmode: tablerecords: 110356 (max_rowid)citation: https://www.ncbi.nlm.nih.gov/pmc/

Metal halide perovskite scintillators encounter unprecedented opportunities in indirect ionizing radiation detection due to their high quantum yields. However, the long scintillation lifetime of microseconds upon irradiation, known as the afterglow phenomenon, obviously limits their fast development. Here, a new type of hybrid X‐ray detector wafer combining direct methylamine lead iodide (MAPbI3) semiconductor and indirect zero‐dimensional cesium copper iodide (Cs3Cu2I5) scintillator through low‐cost fast tableting processes is reported. Due to the fast energy transfer from Cs3Cu2I5 to MAPbI3, the device response time to X‐rays is dramatically reduced by nearly 30 times to 36.6 ns, which enables fast X‐ray detection capability by a large area detector arrays within 1 s. Moreover, Cs3Cu2I5 exists at the grain boundaries of MAPbI3 crystals, and blocks the paths of mobile ions of perovskite, leading to the lowest detectable dose rate of hybrid X‐ray detector is thus reduced by 1.5 times compared with control MAPbI3 direct‐type semiconductor, and 10 times compared with the Cs3Cu2I5 indirect‐type scintillator. The direct/indirect hybrid wafer also exhibits improved operation stability at ambient conditions without any encapsulation. This new kind of hybrid X‐ray detectors provides strong competitiveness by combining the advantages of both direct perovskite semiconductors and indirect perovskite scintillators for next‐generation products.

Read full text (26,316 characters)

Fields

journalAdvanced Science
year2022
pmid35319817
doi10.1002/advs.202103735
licenseThis is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. https://creativecommons.org/licenses/by/4.0/
source_urlhttps://pmc-oa-opendata.s3.amazonaws.com/PMC9130882.1/PMC9130882.1.xml
article_typeresearch-article
source: PubMed Central Open Access Subsetlicence: This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. https://creativecommons.org/licenses/by/4.0/year: 2022id: PMC9130882citation: https://pmc-oa-opendata.s3.amazonaws.com/PMC9130882.1/PMC9130882.1.xml

JSON · full text · full-text JSON

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.