Aqueous cytokine and growth factor levels do not reliably reflect those levels found in the vitreous.

PURPOSE: Recent studies have illuminated the vitreous proteome as a potentially important diagnostic tool that will predict disease progression and response to treatment, in eyes with retinal disease. Studies to date have demonstrated correlations of protein levels between vitreous and aqueous humor. Because these results are un-expected and analysis was only done on a few endpoints, the present study further analyzes the relationship between aqueous and vitreous by probing a wide array of proteins in patients with posterior segment diseases. METHODS: Anterior chamber aqueous fluid was obtained using a limbal approach with a 30 gauge needle. Immediately following, the vitreous sample was obtained via a pars plana approach. A 25 gauge needle with a 1 ml syringe was directed into the mid-vitreous cavity and vitreous fluid was gently aspirated. Aqueous and vitreous samples were then analyzed using the quantitative native protein analysis method called reverse phase protein microarray technology (RPPM). RESULTS: The entire sample population (n=11) was probed against 34 proteins, revealing 8 proteins that significantly correlate, 3 proteins that trend to correlation but fell short of si

source: NCBI PubMed baseline (MEDLINE citations)licence: NLM PubMed terms of use; abstracts as publisheddatabase: /dbs/pubmed_baseline.dbmode: tablerecords: 30770000 (max_rowid)citation: https://pubmed.ncbi.nlm.nih.gov/

PURPOSE: Recent studies have illuminated the vitreous proteome as a potentially important diagnostic tool that will predict disease progression and response to treatment, in eyes with retinal disease. Studies to date have demonstrated correlations of protein levels between vitreous and aqueous humor. Because these results are un-expected and analysis was only done on a few endpoints, the present study further analyzes the relationship between aqueous and vitreous by probing a wide array of proteins in patients with posterior segment diseases. METHODS: Anterior chamber aqueous fluid was obtained using a limbal approach with a 30 gauge needle. Immediately following, the vitreous sample was obtained via a pars plana approach. A 25 gauge needle with a 1 ml syringe was directed into the mid-vitreous cavity and vitreous fluid was gently aspirated. Aqueous and vitreous samples were then analyzed using the quantitative native protein analysis method called reverse phase protein microarray technology (RPPM). RESULTS: The entire sample population (n=11) was probed against 34 proteins, revealing 8 proteins that significantly correlate, 3 proteins that trend to correlation but fell short of significance and 23 proteins that have no correlation between the vitreous and aqueous humor. CONCLUSIONS: Proteins in the aqueous cannot be assumed to correlate with their counterparts in the vitreous.

Read full text or abstract (1,400 characters)

Fields

journalMolecular vision
year2011
doi
meshAdult; Aged; Aged, 80 and over; Aqueous Humor; Cytokines; Female; Gene Expression; Gene Expression Profiling; Humans; Intercellular Signaling Peptides and Proteins; Male; Middle Aged; Organ Specificity; Protein Array Analysis; Proteomics; Retinal Diseases; Vitrectomy; Vitreous Body

Cite this record

MLA
"Aqueous cytokine and growth factor levels do not reliably reflect those levels found in the vitreous." NCBI PubMed baseline (MEDLINE citations), 2011, https://pubmed.go-v.org/record/22128233.

Chicago
"Aqueous cytokine and growth factor levels do not reliably reflect those levels found in the vitreous." NCBI PubMed baseline (MEDLINE citations). 2011. https://pubmed.go-v.org/record/22128233.

APA
NCBI PubMed baseline (MEDLINE citations). (2011). Aqueous cytokine and growth factor levels do not reliably reflect those levels found in the vitreous. https://pubmed.go-v.org/record/22128233

Share card · JSON record

source: NCBI PubMed baseline (MEDLINE citations)licence: NLM PubMed terms of use; abstracts as publishedyear: 2011id: 22128233citation: https://pubmed.ncbi.nlm.nih.gov/22128233

JSON · full text · full-text JSON ·

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.